使用racadm命令修改idrac
本文最后更新于 2024-05-30,文章内容可能已经过时。
ESXi版本的racadm 下载地址:https://www.dell.com/support/home/zh-cn/drivers/driversdetails?driverid=jywk1
ESXi下载的文件名为DellEMC-iDRACTools-Web-ESXi.VIB-9.4.0-3749_A00.tar.gz
通过xftp或者ESXi网页版上传到ESXi的目录中
ESXi目录为/vmfs/volumes/604454ef-89990d88-e0fe-1418776fbf60
xftp可以直接传到根目录/
以根目录为例
# 解压
tar -xvf DellEMC-iDRACTools-Web-ESXi.VIB-9.4.0-3749_A00.tar.gz
# 切换目录
cd /iDRACTools/racadm/ESXi67
# 执行
esxcli software vib install -d Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip
# 结果报错
[MetadataDownloadError]
Could not download from depot at zip:/var/log/vmware/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip?index.xml, skipping (('zip:/var/log/vmware/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip?index.xml', '', "Error extracting index.xml from /var/log/vmware/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip: [Errno 2] No such file or directory: '/var/log/vmware/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip'"))
url = zip:/var/log/vmware/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip?index.xml
Please refer to the log file for more details.
# 报错原因是没传全路径,执行
esxcli software vib install -d /vmfs/volumes/datastore1/iDRACTools/racadm/ESXi67/Racadm-Dell-EMC-Web-9.4.0-3749.VIB-ESX67i.zip
# 安装成功,执行
racadm getsysinfo
安装完成
使用racadm命令获取root用户id;
racadm getconfig -u root
使用racadm命令重置root用户密码;
racadm set iDRAC.Users.2.Password 123456 #123456为重置后的密码
提示密码重置成功。
- 感谢你赐予我前进的力量
赞赏者名单
因为你们的支持让我意识到写文章的价值🙏
本文是原创文章,完整转载请注明来自 枫の屋
评论
匿名评论
隐私政策
你无需删除空行,直接评论以获取最佳展示效果